SYCON 2602 with housing (110/230 VAC)

Print

The SYCON 2602 is an analysis device for limit value monitoring. It enables a demand-controlled regeneration triggering of your softening system or the monitoring of a reverse osmosis. The limit value of the SYCON 2602 analyzer is determined by the indicator used. In addition to the current measured values, the display also shows other information such as the history of the last 100 measurements. In addition, all measurement results are documented on an SD card.

Product information SYCON 2602

  • Monitoring a limit value
  • Residual hardness, total hardness or carbonate hardness (acid capacity)
  • Indicator shortage alarm / BOB functionality
  • Graphic display, menu navigation in German, English, Italian, French, Spanish, Russian, Polish, Dutch and Danish.
  • Easy commissioning using the installation assistant
  • Documentation of all measurement results on an SD card
  • Low maintenance effort thanks to hose pump technology and rinsing of the measuring cell with line pressure
  • Self-calibrating against extraneous light, dirt and turbidity in the water sample
  • Reliable through self-diagnosis and plausibility monitoring of the sensor data during the analysis
  • Maintenance-free full-color sensor
  • Adjustment of the limit value of our H25 and C25 reagents to the unit set in the device
  • Ports:
    • 3 floating outputs:
      • Limit exceeded
      • Device failure
      • Analysis active or BOB message
    • Input for potential-free contact for external analysis triggering or pausing the internal analysis interval

 

The limit is determined by the reagent used in the H25 or C25 series.

Specifications

Parameters value / range
Power supply 85 ... 265 VAC at 47 ... 440 Hz
Power consumption 25 VA (peak)
Protection class I
degree of protection IP54
Ambient temperature 10 ... 45 °C
Measuring water temperature 5 ... 40 °C
Sample Port Hose 6mm
Dimensions (W x L x D) 274x275x130mm
Weight 3.8kg
Operating pressure 0.5 .. 5 bar
Reagents H25 for residual / total hardness
C25 for carbonate hardness / acid capacity
Durability reagent 24 months
Article number 30-210160
Article description SYCON 2602 in housing (110/230 VAC)

We manufacture our indicators ourselves. Only high-quality raw materials are used. Each production batch is checked in our laboratory for the specified limit value. 

Reagent Article number Threshold
   Single Bottle Value Pack  °dH °f ppm CaCo3 °e
H25-0.02 32-084115 32-484115 0.02 0.04 0.4 0.03
H25-0.05 32-084125 32-484125 0.05 0,1 1 0.06
H25-0.1 32-084135 32-484135 0,1 0.2 2 0.13
H25-0.2 32-084145 32-484145 0.2 0.4 4 0.25
H25-0.3 32-084155 32-484155 0.3 0.6 3 0.38
H25-0.5 32-084165 32-484165 0.5 1.0 10 0.63
H25-1 32-084175 32-484175 1 2.0 20 1.25
H25-2 32-084185 32-484185 2 4.0 40 2.5
H25-3 32-084195 32-484195 3 6.0 60 3,8
H25-5 32-084205 32-484205 5 10 100 6,3
H25-10 32-084215 32-484215 10 20 200 12.6

 

 We manufacture our reagents ourselves. Only high-quality raw materials are used.Each production batch is checked in our laboratory for the specified limit value. 

Reagent Article number Threshold
   Single Bottle Value Pack  °dH °f ppm CaCo3 mmol/L (KS4.3)
C25-1  32-086125 32-486125  1  2 20 0.357
C25-1.5  32-084125 32-484125  1.5  3 30 0.535
C25-2  32-084135 32-484135  2  4 40 0.714
C25-3  32-084145 32-484145  3  6 60 1,071

 

We also offer accessories for our devices for easy installation and maintenance

Description Article number Description
SYCON connection set  33-000701 For connecting a SYCON analyzer to a sample line with 1/2" or 1/4"
  • Reducing nipple 1/2" to 1/4"
  • Stainless steel ball valve 1/4" on 6mm plastic hose for shutting off, e.g. during maintenance
  • 5m plastic hose suitable for SYCON inlet and outlet
Pressure reducer with
filter incl. manometer for SYCON
 33-090738 Recommended for inlet pressures above 2 bar
  • Control range 0 -4 bar
  • Inlet pressure up to 13 bar
  • integrated pressure gauge
  • including filter with 20 µm pore size
Cleaning set SYCON Clean  30-010900 Cleaning set for measuring combs
  • Storage box
  • Instructions
  • Gloves
  • Brushes
  • Funnel
  • Cleaning liquid FIT3000 (1000 ml)
Cleaning liquid FIT3000  32-089100 Cleaner for measuring chambers (1000 ml)
Maintenance
set SYCON 2500 - SYCON 2602
 32-089100 Spare parts set for SYCON 2500 - 2602
  • O-rings
  • Peristaltic pump cartridge
  • Indicator hoses

 

 

Attachments

Ask about this product

Our product range

  • With the online analyzers of the Sycon series from RLS Wacon, individual parameters can be continuously monitored automatically. Our devices
    Read More
  • RLS Wacon offers you a wide range of test kits for the determination of water parameters. In addition to many
    Read More
  • RLS Wacon offers the reagent suitable for your analyzer. In addition to the reagents for our Sycon analyzers, the delivery
    Read More