RLS Wacon | Sparte Wasser | Produkte | Analysengeräte | Sycon 2502

SYCON 2802 on wall mounting plate (110/230 VAC)

Print

The SYCON 2802 is a titration device for measuring water hardness or carbonate hardness. Compared to the SYCON 2702, the online analysis device has two more relays, which makes a large number of new connection variants possible. There is also an RS485 interface with Modbus RTU protocol and another input contact. An additional, programmable second limit value enables the monitoring of a water intersection or a pre-alarm. The additional relay contacts make it possible to control an external cooling water valve for a sample cooler.

Product information SYCON 2802

      • Monitoring of a freely programmable limit value
      • Measurement of residual hardness, total hardness or carbonate hardness (acid capacity)
      • Graphic display, menu navigation in German, English, Italian, French, Spanish, Russian, Polish, Dutch and Danish.
      • Easy commissioning using the installation assistant
      • Documentation of all measurement results on an SD card
      • Low maintenance effort thanks to hose pump technology and rinsing of the measuring cell with line pressure
      • Self-calibrating against extraneous light, dirt and turbidity in the water sample
      • Reliable through self-diagnosis and plausibility monitoring of the sensor data during the analysis
      • Maintenance-free full-color sensor
      • Ports:
        • 4 potential-free outputs:
          • Limit exceeded
          • Exceeding the limit value / falling below the limit value / low indicator level
          • Device failure
          • Analysis active / cooling water valve  / Indicator level low
        • Current interface configurable as 0 - 20mA or 4 -20mA for measured value output or status message
        • Input for potential-free contact for triggering an external analysis, water meter for quantity interval or pausing the internal analysis interval
        • Input for remote reset via external control
        • Modbus RTU for querying the measured values ​​and device parameters by a PLC

The measuring range is determined by the reagent used in the H25 or C25 series.

Specifications

Parameters value / range
Power supply 85 ... 265 VAC at 47 ... 440 Hz
Power consumption 25 VA (peak)
Protection class I
degree of protection IP 43 (housing version IP 54)
Ambient temperature 10 ... 45 °C
Measuring water temperature 5 ... 40 °C
Sample Port Hose 6mm
Dimensions (W x L x D) 274x275x130mm
Weight 1.9kg
Operating pressure 0.5 .. 5 bar
Reagents H25 for residual / total hardness
C25 for carbonate hardness / acid capacity
Durability reagent 24 months

 

 

 

Article number 30-310164
Article description SYCON 2802 with housing (110/230 VAC)

We manufacture our reagents ourselves. Only high-quality raw materials are used. Each production batch is checked in our laboratory for the specified limit value. 

Reagent Article number Measuring range
   Single Bottle Value Pack  °dH °f ppm CaCo3 °e
H25-0.02 32-084115 32-484115 0.012 - 0.12 0.021 - 0.214 0.21 - 2.14 0.025 - 0.15
H25-0.05 32-084125 32-484125 0.02 - 0.2 0.036 - 0.357 0.36 - 3.57 0.025 - 0.25
H25-0.1 32-084135 32-484135 0.03 - 0.3 0.054 - 0.536 0.54 - 5.36 0.038 - 0.375
H25-0.2 32-084145 32-484145 0.06 - 0.6 0.11 - 1.07 1.1 - 10.7 0.08 - 0.75
H25-0.3 32-084155 32-484155 0.09 - 0.9 0.16 - 1.161 1.6 - 16.1 0.12 - 1.12
H25-0.5 32-084165 32-484165 0.15 - 1.5 0.27 - 2.68 2.7 - 26.8 0.19 - 1.87
H25-1 32-084175 32-484175 0.3 - 3 0.54 - 5.36 5.4 - 53.6 0.38 - 3.75
H25-2 32-084185 32-484185 0.6 - 6 1.1 - 10.7 10.7 - 107.1 0.76 - 7.51
H25-3 32-084195 32-484195 0.9 - 9 1.6 - 16.1 16.1 - 160.1 1.13 - 11.2
H25-5 32-084205 32-484205 1.5 - 15 2.7 - 26.8 26.8 - 267.9 1.88 - 18.8
H25-10 32-084215 32-484215 3 - 30 5.4 - 53.6 53.6 - 535.7 3.76 - 37.6

 

 We manufacture our reagents ourselves. Only high-quality raw materials are used.Each production batch is checked in our laboratory for the specified limit value. 

Reagent Article number Measuring range
   Single Bottle Value Pack  °dH °f ppm CaCo3 mmol/L (KS4.3)
C25-1  32-086125 32-486125  0.3 - 7.5 0.5 - 13.4  5,3 - 134 0.11 - 2.68
C25-1.5  32-084125 32-484125  0.5 - 11.5 0.8 - 20.5  8.0 - 80.1 0.16 - 4.11
C25-2  32-084135 32-484135  0.6 - 15.0 1.1 - 26.8  10.6 - 268 0.21 - 5.36
C25-3  32-084145 32-484145  0.9 - 22.5 1.6 - 40.2  16 - 402 0.32 - 8.04

 

We also offer accessories for our devices for easy installation and maintenance

Description Article number Description
SYCON connection set  33-000701 For connecting a SYCON analyzer to a sample line with 1/2" or 1/4"
  • Reducing nipple 1/2" to 1/4"
  • Stainless steel ball valve 1/4" on 6mm plastic hose for shutting off, e.g. during maintenance
  • 5m plastic hose suitable for SYCON inlet and outlet
Pressure reducer
with filter incl.
manometer for SYCON
 33-090738 Recommended for inlet pressures above 2 bar
  • Control range 0 -4 bar
  • Inlet pressure up to 13 bar
  • integrated pressure gauge
  • including filter with 20 µm pore size
Cleaning set SYCON Clean  30-010900 Cleaning set for measuring combs
  • Storage box
  • Instructions
  • Gloves
  • Brushes
  • Funnel
  • Cleaning liquid FIT3000 (1000 ml)
Cleaning liquid FIT3000  32-089100 Cleaner for measuring chambers (1000 ml)
Maintenance
set SYCON 2702- 2802 / FE / BOB
 32-089100 Spare parts set for SYCON 2702 - 2802 / FE / BOB
  • O-rings
  • Peristaltic pump cartridge
  • Reagent hoses

Attachments

Ask about this product