SYCON BoB
The SYCON BoB is an online analysis device for monitoring soft water for operation without constant supervision for safe operation during 72 hours (BOB 72 hours). The additional relay contacts make it possible to control an external cooling water valve for a sample cooler. The device status can be connected to remote maintenance via the existing RS-485 interface with Modbus-RTU protocol.
Product information SYCON BOB
- TÜV certified according to VdTÜV leaflet BP WAUE 0100 for operation without constant supervision for safe operation for 72 hours (BOB 72 hours)
- Use in large water boilers with salty, low-salt or salt-free driving with a limit value of 0.01 mmol/l or 0.05 °dH according to EN12953-10 (indicator H25-0.1)
- Use in circulation tanks with a limit value of 0.005 mmol/l or 0.03 °dH according to EN12952-12 (indicator H25-0.05)
- Monitoring of boiler feed water, boiler water or condensate return
- Level monitoring of the indicator by a level probe
- Graphic display, menu navigation in German, English, Italian, French, Spanish, Russian, Polish, Dutch and Danish.
- Easy commissioning using the installation assistant
- Documentation of all measurement results on an SD card
- Low maintenance effort thanks to hose pump technology and rinsing of the measuring cell with line pressure
- Self-calibrating against extraneous light, dirt and turbidity in the water sample
- Reliable through self-diagnosis and plausibility monitoring of the sensor data during the analysis
- Maintenance-free full-color sensor
- Ports:
- 4 potential-free outputs:
- Limit exceeded
- Exceeding the limit value / falling below the limit value / low indicator level
- Device failure
- Analysis active / cooling water valve / Indicator level low
- Current interface configurable as 0 - 20mA or 4 -20mA for measured value output or status message
- Input for potential-free contact for triggering an external analysis, water meter for quantity interval or pausing the internal analysis interval
- Input for remote rest via external control
- Modbus RTU for querying the measured values and device parameters by a PLC
- 4 potential-free outputs:
Specifications
Parameters | value / range |
Power supply | 85 ... 265 VAC at 47 ... 440 Hz |
Power consumption | 25 VA (peak) |
Protection class | I |
degree of protection | IP54 |
Ambient temperature | 10 ... 45 °C |
Measuring water temperature | 5 ... 40 °C |
Sample Port | Hose 6mm |
Dimensions (W x L x D) | 274x275x130mm |
Weight | 3.8kg |
Operating pressure | 0.5 .. 5 bar |
Reagents | H25-0.05 H25-0.1 |
Durability reagent | 24 months |
Approved according to VdTÜV leaflet BP WAUE 0100
Artikelnummer | 30-610164 |
Artikelbezeichnung | Analysis device SYCON BOB in housing, 230V |
We manufacture our reagents ourselves. Only high-quality raw materials are used. Each production batch is checked in our laboratory for the specified limit value.
Reagent | Article number | Threshold | ||||
Single Bottle | Value Pack | °dH | mmol/l | Boiler type | Norm | |
H25-0.05 | 32-084125 | 32-484125 | 0.03 | 0.005 | Circulation boiler | EN12952-12 |
H25-0.1 | 32-084135 | 32-484135 | 0.05 | 0.01 | Large water boiler | EN12953-10 |
We also offer accessories for our devices for easy installation and maintenance
Description | Article number | Description |
SYCON connection set | 33-000701 | For connecting a SYCON analyzer to a sample line with 1/2" or 1/4"
|
Pressure reducer with filter incl. manometer for SYCON |
33-090738 | Recommended for inlet pressures above 2 bar
|
Cleaning set SYCON Clean | 30-010900 | Cleaning set for measuring combs
|
Cleaning liquid FIT3000 | 32-089100 | Cleaner for measuring chambers (1000 ml) |
Maintenance set SYCON 2702- 2802 / FE / BOB |
32-089100 | Spare parts set for SYCON 2702 - 2802 / FE / BOB
|
Attachments
-
Flyer SYCON BoB
pdf | 1.27 MB | 295 hits -
Bedienungsanleitung SYCON BoB
pdf | 3.62 MB | 879 hits